1Z0-489 SPARC M6-32 and SPARC M5-32 Servers Installation Essentials

Posted by

Exam Number: 1Z0-489
Exam Title: SPARC M6-32 and SPARC M5-32 Servers Installation Essentials
Associated Certification Paths: SPARC M6-32 and SPARC M5-32 Server Certified Implementation Specialist

Duration: 120 minutes
Number of Questions: 79
Passing Score: 69%
Validated Against:  This exam is validated against M6-32 and M5-32.
Format: Multiple Choice

Complete Recommended Training
Complete the training below to prepare for your exam (optional):

PTR/INT Only SPARC M5-32 Server Installation and Maintenance (for Partners only)

Additional Preparation and Information
A combination of Oracle training and hands-on experience (attained via labs and/or field experience) provides the best preparation for passing the exam.

SPARC M5-32 Servers Overview
Describe the target workloads for the SPARC M5-32 Server
Describe the key differentiators of the SPARC M5-32 Server processor architecture
Describe how the System Interconnect works
Describe Memory population rules
Describe how the System Clock works
Describe how PCIe cards are populated
Describe the PCIe root complex structure and IO card population guidelines
Describe the Power and Cooling system, including redundancy and air flow
Describe the Fan Unit redundancy
Define the Power Supply redundancy and power grid mapping
Use the Operator Panel
Describe memory configuration guidelines
Explain the SPARC M5-32 Server physical domain technology
Differentiate the core capabilities of SPARC M5-32 Server virtualization options (e.g., Oracle VM Server for SPARC, Solaris Zones)

Enterprise Installation Standards (EIS)
Use the Enterprise Installation Service methodology
Setup and generate self-contained installation documentation
Create an installation configuration plan
Create a test procedures plan
Perform system hardware acclimatization steps
Label and route cables.
Describe the electrical grounding requirements
Describe Oracle Solaris installation requirements
Describe Service processor requirements
Define boot disk layout and mirroring

SPARC M5-32 Server Installation
Implement measures to prevent electrostatic discharge
Configure the service processor
Secure the service processor
Update firmware
Configure Physical Domains according to customer requirements
Perform host power on and Power On Self Test (POST)
Perform the initial boot and configuration of Solaris
Test CPU and memory with Sun Validation Test Suite (SunVTS)
Setup and configure Auto Service Request (ASR)
Run Snapshot and Explorer
Troubleshoot common installation issues

SPARC M5-32 Server Troubleshooting and Diagnostics
Describe field replaceable components that may apply to basic installation and configuration
Verify system serial number
Identify the CPU location from within Solaris and from the Service processor when errors are detected
Map the CPU to the CMU, and the CMU to the DCU
Perform PCIe card and riser removal and installation
Use server management tools, (e.g., ILOM BUI, Ops Center, and ipmi)
Use server monitoring tools (e.g., email, snmp, snapshot, explorer, ILOM BUI, Ops Center )
Collect system error and state information (e.g., ILOM snapshot and Solaris Explorer)

QUESTION 1
A customer provides you with their NTP server information. In which two places do you need to configure it?

A. SP
B. SPP
C. OBP
D. Solaris

Answer: B,D

QUESTION 2
Before performing a firmware upgrade, you must first check the keyswitch property for each host. What must it be set to for the firmware upgrade to work?

A. Normal
B. Locked
C. Diag
D. Open

Answer: D

QUESTION 3
Given a SPARC M5-32 server in which each CMU has 2x M5 processors, each processor has 2x memory controllers, and each memory controller can have 2x BoB, how many memory modules/ sections can there be in each CMU?

A. l
B. 2
C. 4
D. 8

Answer: C

QUESTION 4
Assuming that HOST2 is composed of only DCU2, which two targets report the type of CPUs that belong to this DCU?

A. /System/DCUs/DCU_2 cpu- summary
B. /System/Processor type
C. /Servers/PDomains/PDoma1n_2/System/Processors summary- description
D. /Servers/DCU_2/Processors model

Answer: A,D

Reference:
https://docs.oracle.com/cd/E19102-01/n810.srvr/819-2741-10/subassembly_hot_replace.html

QUESTION 5
Which three options are supported memory population options for the SPARC M5-32 server?

A. CMU with no memory/DIMM populated
B. CMU with 1/4 populated with DIMM Q
C. CMU with 1/2 populated with DIMM
D. CMU with full populated with DIMM
E. CMU with 1/8 populated with DIMM

Answer: B,C,E

Click here to view complete Q&A of 1Z0-489 exam
Certkingdom Review
, Certkingdom PDF Torrents

MCTS Training, MCITP Trainnig

Best Oracle 1Z0-489 Certification, Oracle 1Z0-489 Training at certkingdom.com

 

Click to rate this post!
[Total: 0 Average: 0]